Problem
I observe that when a new step (any Action Repository) is added to an Activity Node which is already enclosing some actions, the latest steps is not visible. In addition, it is not visible even after resizing the activity node screen (refer below figures).
...
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
Perspective- 01 |
🔌 Background
Mentioning the pre-requisite related information
Solution
The model must enclose atleast one Activity Node
The existing or new Activity Node must enclose in-prior minimum 3-4 actions
Solution
This issue can be solved by following below steps:
Go to Display Settings and consider Scale and Layout section
...
2. Change the first dropdown (“Change the size of text, apps, and other items”) to 125%
...
3. Refresh / Restart the respective project (or Re-open the respective Activity Diagram file) and the issue will be resolved
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
| ||||||||
Key Concept |
...
Scaling: Such issues are found in the conditions when the display scaling has been modified or has not been set to the value which is of need. Hence, it is recommended to consider the changes in the Display Scaling accordingly to meet the respective task needs or requirements. This kind of issue generally appears with laptops which have lot of new resolution options and other settings |
...